Maintenance Object Repair Procedure
Error Log Entries and Test to Clear Values
Table 8-327. MET Line Error Log Entries
Error
Aux
Type
Data
Associated Test
1
0
0
Any
1 (a)
40987
None
18 (b)
0
busyout port
UUCSSpp
130 (c)
None
257 (d)
40988
None
513 (e)
40965
Hybrid Line Station
Audits test (#61)
769
Port Diagnostic test
(#35)
1025
Hybrid and Conf.
Circuits test (#57)
1537 (f)
40968
None
1793
TDM NPE Crosstalk
test (#6
2049 (g)
32770
2049 (h)
40967
3840 (i)
40989
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
2.
Major or Minor alarms MO may be downgraded to Warning alarms based on the values used in the set options
command.
Notes:
a. The data link between the port and the terminal is not operational (i.e., the
port circuitry has detected an off-board problem). Verify that the MET set is
connected and that the EPF (Electronic Power Feed) test passes. If data
transmission problems are experienced, check for defective wiring or a
defective voice terminal, or move terminal electrically closer to the switch
(i.e., reduce the length of the wiring between the terminal and the switch).
If the problem persists, replace the circuit pack. Once the problem is
resolved, the system retires the alarm after a predetermined time delay.
8-764
Issue 1 May 2002
On/Off
Alarm Level
Board
Any
Any
WARNING
OFF
WARNING
ON
MINOR
OFF
2
WARNING
WARNING
OFF
MINOR
ON
2
WARNING
MINOR
ON
2
WARNING
MINOR
OFF
2
WARNING
MINOR
ON
2
WARNING
Test to Clear Value
test port UUCSSpp sh r 1
release port UUCSSpp
test port UUCSSpp sh
test port UUCSSpp sh r 4
test port UUCSSpp l r 3
test port UUCSSpp l r 3
test port UUCSSpp l r 3
555-233-142