UDS1-BD (UDS1 Interface Circuit Pack)
Table 8-541. Test #1215 Inject Single Bit Error Test — Continued
Error
Test
Code
Result
Description / Recommendation
2000
ABORT
Response to the test was not received within the allowable time period. This
may be due to hyperactivity. Error Type 1538 in the error log indicates
hyperactivity. The hyperactive circuit pack is out of service, and one or more of
the following symptoms may be exhibited.
1. The UDS1-BD tests (such as Tests #138 and #139) are aborting with error
2. The tests run on the ports of this circuit pack are returning a no-board
3. A busyout or a release command has no effect on the test results.
4. A list config command shows that the circuit pack and the ports are
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
555-233-142
code 2000.
result.
properly installed.
NOTE:
When hyperactivity occurs, the circuit pack is isolated from the system,
and all of its trunks are placed into the out-of-service state. The system
will try to restore the circuit pack within 15 minutes. When no faults are
detected for 15 minutes, the UDS1 interface circuit pack is restored to
normal operation. Every trunk for the UDS1 interface circuit pack is then
returned to the in-service state. Hyperactivity is often caused by the
associated facility. In such a case, faults (such as slips, misframes, or
blue alarms) would be entered in the error log. In addition, many
hardware errors would be logged against the associated trunk circuits. If
the facility is OK and the error occurs again after 15 minutes, replace the
circuit pack.
Continued on next page
Issue 1 May 2002