Avaya S8700 Maintenance Manual page 48

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance Object Repair Procedure
Error Log Entries and Test to Clear Values
Table 8-314. DS1 Interface Circuit Pack Maintenance Error Log Entries
Error
Aux
Type
Data
Associated Test
1
0
0
Any
1(a)
0
Circuit pack removed or
SAKI test (#53)
18(b)
0
busyout board UUCSS
23(c)
0
125(d)
None
None
257(e)
6553
Control Channel Loop
5
test (#52)
1538(f)
Any
Hyper activity
1793
Any
NIC Loss Of Signal
2049(g)
Any
NT PC Failure
2305
Any
IP Address Inconsistency
2561
Any
Ping Error
3841(h)
4358
3999(i)
Any
None
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
2.
If ports are assigned to the circuit pack, then a minor alarm is raised. If no ports are assigned to the circuit pack,
then a warning alarm is raised. The alarm is raised after the circuit pack has been missing for a period of 15
minutes. Warning alarms are also raised against any ports administered on the circuit pack.
3.
Minor alarms on this MO may be downgraded to warning alarms based on values set in the set options
command.
8-744
Issue 1 May 2002
On/Off
Alarm Level
Board
Any
Any
MINOR
ON
2
WARNING
WARNING
OFF
WARNING
OFF
MINOR
ON
3
WARNING
MINOR
ON
MINOR
ON
3
WARNING
MINOR
3
WARNING
MINOR
3
WARNING
MINOR
3
WARNING
Log Only
Continued on next page
Test to Clear Value
test board UUCSS
release board UUCSS
add ds1 UUCSS
test board UUCSS l r 2
test board UUCSS l r 2
reset board UUCSS
test board UUCSS l r 2
test board UUCSS l r 5
555-233-142

Advertisement

Table of Contents
loading

Table of Contents