PKT-INT (Packet Interface)
Read and Clear Board Counters (#887)
This test involves sending commands to read circuit pack error counters located
on the IPSI circuit pack's Packet Interface circuit. It also verifies the message
interface between the server and the Packet Interface circuit.
This test checks different circuit pack counters.
Running this test on the IPSI circuit pack's Packet Interface circuit reads and
clears the Parity Error counter and FIFO Overflow counter.
For an active Packet Interface circuit, information about the number of bad
Translation location is sent to maintenance software as an in-line error from the
circuit pack so it is not necessary to read a counter location.
Table 8-397. Test #887 Read and Clear Board Counters
Error
Test
Code
Result
Description / Recommendation
1006,
ABORT
The IPSI circuit pack's Packet Interface circuit is out of service, so normal
1137
maintenance tests do not run on the circuit pack.
1. Enter the reset packet-interface Uc command to reset the Packet
2000
ABORT
Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 3 times.
2500
ABORT
Internal system error
1. Retry the command.
NO
The IPSI circuit pack's Packet Interface circuit is administered, but is not
BOARD
detected as being physically present.
1. If the IPSI circuit pack is present, replace it.
2. If not, insert a TN2312 IPSI circuit pack in the administered slot, and rerun
555-233-142
Interface circuit. For repair procedures, see
the Packet Interface Reset test.
the test.
Table 8-394 on page
8-938,
Continued on next page
Issue 1 May 2002
8-945