Avaya S8700 Maintenance Manual page 34

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance Object Repair Procedure
If the circuit pack is properly administered and the red LED is still on, follow
the instructions for LED Alarms with Error Type 1 in Chapter 7.
b. Error Type 2—NT is down and the system attempts to reset the board. If
the reset fails, the board is probably bad.
1. Replace the circuit pack.
c. Error Type 18—The circuit pack has been busied out.
1. Release the board (release board UUCSS).
d. Error Type 23 and 1025: The MAPD-BD circuit pack is not completely
administered. In addition to insertion, the MAPD circuit pack must have all
of the following administration:
The MAPD circuit pack differs from others in that inserting it into the switch
backplane is not enough to make the board usable.
e. Error Type 125, no Aux Data:—A wrong circuit pack is inserted in the slot
where this circuit pack is logically administered. To resolve this problem,
either:
1. Remove the wrong circuit pack and insert the logically administered
f. Error Type 257—This error is associated with the Common Port circuit
pack maintenance test. See
page 8-1374
8-730
Issue 1 May 2002
Completely remove the MAPD-BD from the system:
a. Shut down NT (see
b. Remove any administered DS1 trunks, access endpoints, or
PRI endpoints associated with the circuit pack from their
respective trunk groups.
c. Remove the DS1 (remove ds1 UUCSS) and circuit pack
(change circuit pack UUCSS) administration.
Have an entry in the circuit plan (change circuit pack)
Be administered as DS1 (add ds1 UUCSS)
circuit pack
or
Re-administer this slot (change circuit-pack) to match the circuit
pack inserted.
''XXX-BD (Common Port Circuit Pack)'' on
for details.
''Shutting Down NT on the
TN802'')
555-233-142