Avaya S8700 Maintenance Manual page 292

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance Object Repair Procedure
Table 8-418. Test #35 Battery Feed Test — Continued
Error
Test
Code
Result
Description / Recommendation
2000
ABORT
Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
The port's battery feed chip is unable to supply sufficient power to the terminal
equipment. This could be a marginal test, and the terminal equipment may be
operating satisfactorily.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to fail, determine whether the customer is experiencing
PASS
The port's battery feed chip can provide power to the station equipment to
detect on-/off-hook, but may not be able to supply power for touch tones. If
touch tones are inoperative on this station, then replace the circuit pack
because this port is inoperative.
User-reported troubles on this port should be investigated by using other port
tests, by examining station wiring, or by examining the station.
8-988
Issue 1 May 2002
problems on this line. Replace the circuit pack only if the customer is
experiencing problems.
Continued on next page
555-233-142

Advertisement

Table of Contents
loading

Table of Contents