Avaya S8700 Maintenance Manual page 123

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

MODEM-PT (Modem Pool Port)
Table 8-349. Test #98 Modem Pool Conversion Resource
Loop-Around Test — Continued
Error
Test
Code
Result
Description / Recommendation
2323
ABORT
The Maintenance Test circuit pack digital port allocated for this test did not
disconnect properly. This error is more closely related to the Maintenance Test
circuit pack digital port used for this test than the TN758 Pooled Modem circuit
pack itself. Therefore, any hardware testing or replacement activities will focus
on the Maintenance Test circuit pack.
1. Wait 1 minute and attempt the test again up to 5 times.
2324
ABORT
The digital portion of the tested Modem Pool port did not disconnect properly.
1. Wait 1 minute and attempt the test again.
2. If the test continues to abort, replace the Pooled Modem circuit pack and
2325
FAIL
The Modem Pool port did not respond with an on-hook message when the
connection to the TN711 Maintenance/Test digital port was broken, indicating a
likely problem with the TN758 Pooled Modem circuit pack.
1. Busyout both of the TN758 Pooled Modem conversion resources on the
2. If the test continues to fail, replace the Pooled Modem circuit pack and
FAIL
The Loop-around test failed, the loop-back data did not match the original data.
1. Repeat Test #98.
2. If the test fails again, replace the Pooled Modem circuit pack.
PASS
The port can correctly transmit/receive data.
555-233-142
retest.
circuit pack containing the failing conversion resource.
retest.
Continued on next page
Issue 1 May 2002
8-819

Advertisement

Table of Contents
loading