TIE-DS1 (DS1 Tie Trunk)
k. Error Type 2562 — Retry Failure error. This error is logged only. It is not a
hardware failure and hence does not start any testing or generate any
alarms. This error comes from call processing and is generated when a
second attempt (retry) to seize an outgoing trunk fails.
l. Error Type 2817 — Glare error. This error is logged only. It is not a
hardware failure and hence does not start any testing or generate any
alarms. This error is the result of a simultaneous seizure of a 2-way trunk
from both the near and the far ends. Attempt to place the call again. If the
error persists, execute the DS1 Tie Trunk Seizure test (#136) and follow its
outlined procedures.
m. Error Type 3840 — Port Audit and Update test (#36) failed due to an
internal system error. Enter status trunk command, and verify the status
of the trunk. If the trunk is out-of-service, then enter release trunk
command to put it back to in-service. Retry the test command.
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. For example, by clearing error codes associated with the
NPE Crosstalk test (#6), you may also clear errors generated from other tests in
the testing sequence.
Order of Investigation
NPE Crosstalk test (#6)
Conference Circuit test (#7)
DS1 Tie Trunk Seizure test (#136)
Port Audit and Update test (#36)
1.
D = Destructive; ND = Nondestructive
For TN767B vintage 8 or 9 circuit packs, a failure of Test #136 causes a
subsequent failure of Test #7. Test #136 is part of the short sequence and
generates off-board alarms Test #7 is part of the long sequence and generates
on-board alarms. Before entering busyout, release, reset or test board long
commands, check the vintage number of the circuit pack with list configuration
board UUCSS. If it is TN767B vintage 8 or 9, do not use the above commands
until first making sure that Test #136 passes via test board short. Otherwise,
extraneous on-board alarms may be generated.
555-233-142
Short Test
Long Test
Sequence
Sequence
X
X
X
X
X
X
Issue 1 May 2002
1
D/ND
ND
ND
ND
ND
8-1139