Avaya S8700 Maintenance Manual page 458

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance Object Repair Procedure
Table 8-491. TIE Trunk Error Log Entries — Continued
Error
Aux
Type
Data
Associated Test
769(l)
57481
EPF M and E Lead
(#74)
1025(m)
Any
None
1281(l)
Any
EPF M and E Lead
(#74)
1537
Looparound and
Conference (#33)
1793
Tie Trunk Seizure
(#73) (Dial Test #747
for TN439)
2049
NPE Crosstalk (#6)
2305(n)
57424
None (l)
50944
2561(o)
0
None
2562(p)
16665
2817(o)
0
None
2817(q)
52992
3073(o)
0
None
3840(r)
8000
Transmission tests
(ATMS)(#844-848)
3841(r)
Transmission tests
(ATMS)(#844-848)
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
2.
Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the set options
command. If the MINOR alarm is not downgraded by the set options values, then the MINOR alarm will be
upgraded to a MAJOR alarm if 75% of the trunks in this trunk group are alarmed. These errors, if applicable,
always log a MINOR alarm for TN439 and TN497.
8-1154
Issue 1 May 2002
Alarm
On/Off
Level
Board
MAJOR
ON
MINOR
2
WARNING
MAJOR
OFF
MINOR
2
WARNING
MAJOR
ON
MINOR
2
WARNING
MAJOR
ON
MINOR
2
WARNING
MAJOR
OFF
MINOR
2
WARNING
MAJOR
ON
MINOR
2
WARNING
WARNING
OFF
MINOR
OFF
OFF
MINOR
OFF
Test to Clear Value
test port UUCSSpp sh r 3
test port UUCSSpp sh r 3
test port UUCSSpp l r 3
test port UUCSSpp sh r 2
test port UUCSSpp l r 3
test analog-testcall
test analog-testcall
UUCSSpp r 2
Continued on next page