Table 8-330. Test #35 Port Diagnostic Test — Continued
Error
Test
Code
Result
Description / Recommendation
2100
ABORT
Could not allocate the necessary system resources to run this test. This could
be due to a failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
Battery Feed test failed. This port is out-of-service.
1. Other ports on this circuit pack are not affected. Place user on a different
2. Replace circuit pack when available.
PASS
Battery Feed test passed. Current flow is properly detected for this port.
1. If users are reporting problems, examine connections to the port.
0
NO
The test could not relate the internal ID to the port (no board). This could be
BOARD
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list
2. If the board was found to be correctly inserted in step 1, issue the busyout
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the linkage
555-233-142
port, if available, until a replacement circuit pack can be obtained.
config command, and resolve any problems that are found.
board command.
between the internal ID and the port. If this is not the case, check to
ensure that there is a valid board inserted.
Continued on next page