Avaya S8700 Maintenance Manual page 645

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

VAL-PT (Voice Announcements over LAN Packet/Port)
VAL-PT (Voice Announcements over
LAN Packet/Port)
MO's Name (in
Alarm Log)
Alarm Level
VAL-PT
MAJOR
VAL-PT
MINOR
VAL-PT
WARNING
1.
UU is the universal cabinet number (1 for PPN, 2 - 3 for EPNs). C is the carrier designation (A, B, C, or D). SS
is the number of the slot where the circuit pack resides (01–10). pp is the 2-digit port number (01, 02, etc.).
An RSCL (remote socket control link) connects the VAL and the server to pass
call-control and other management information. Since one link serves every port
on the circuit pack, maintenance of the RSCL is part of the VAL circuit pack
maintenance.
VAL Congestion Controls
The switch activates congestion controls on VAL when it detects buffers
exceeding the threshold. The switch releases the congestion controls when the
VAL reports that its buffer level has returned to normal levels.
If congestion:
Persists for a 14-minute interval
Exhausts buffers
Ceases for 12 minutes
Error Log Entries and Test to Clear Value
Error
Aux
Type
Data
Associated Test
1
0
0
Any
1 (a)
0
SCOTCH Sync
Loop-Around test (#1275)
257 (b)
0
3585 (c)
0, 1
TDM Loop-Around test (#1285) MAJOR
1.
There is no short test sequence for this MO. Every test is available in the long test sequence. Refer to each
appropriate test's description, and follow its recommended procedures.
555-233-142
Initial Command to Run
test port UUCSSpp long
test port UUCSSpp long
test port UUCSSpp
Then the switch:
Raises MINOR alarm
Raises MINOR alarm
Retires MINOR alarm
Alarm
Level
Any
MINOR
WARNING OFF
1
Full Name of MO
VAL Port Maintenance
VAL Port Maintenance
VAL Port Maintenance
On/Off
Board
Test to Clear Value
Any
test port UUCSSpp l
ON
test port UUCSSpp l r 3
ON
test port UUCSSpp l r 3
Continued on next page
Issue 1 May 2002
8-1341

Advertisement

Table of Contents
loading

Table of Contents