Avaya S8700 Maintenance Manual page 430

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance Object Repair Procedure
2. Otherwise, enter the display errors command, and follow corrective
Table 8-480. Error Log Entries for Slip Errors
Circuit Pack Name
DS1 Interface
Tone-Clock
UDS1 Interface
DS1C Circuit Pack
3. If 1025 errors persist, see
f. Error Type 1281
pack has detected a loss of timing signal from the system synchronization
reference. The Tone-Clock circuit pack has switched synchronization
references.
1. Resolve any errors logged against the SYNC or STRAT-13 MOs.
2. See
Error Type 1282
synchronized to a DS1 facility and that the reference frequency provided by
the DS1 drifted beyond a range that could be tracked by the TN2182.
Therefore the TN2182 is no longer synchronized to that DS1 reference. If
a second DS1 is available, the tone-clock may be synchronized to that
reference. If no secondary DS1 reference is available, the tone-clock will
run off of its internal clock. This may result in slips being reported by the
tone-clock and every DS1 facility.
8-1126
Issue 1 May 2002
procedures for any other TDM-CLK, TONE-BD, SYNC, and
DS1C-BD, errors logged, except for those in
Error Log
Name
DS1-BD
TDM-CLK
UDS1-BD
DS1C-BD
and follow the procedures in
This error is an indication that the Tone-Clock circuit
''SYNC (Port-Network Synchronization)''
"Approach to Troubleshooting" section, if the error is not resolved by
step 1
Indicates that the TN2182 tone-clock was
Table
Error Log Entry
for Slips
3073 to 3160
1025
3073 to 3160
3329
''SYNC (Port-Network Synchronization)''
''Troubleshooting
Approach''.
maintenance, in the
8-480.
555-233-142