PPP-PT (Control LAN Packet/Port)
TCP/IP Ping Test (#1281)
This nondestructive test fails if the endpoint fails to respond. Use this test to
check the circuitry in the data path for a peer-to-peer IP layer connection.
Table 8-409. Test #1281 TCP/IP Ping Test
Error
Test
Code
Result
Description / Recommendation
1, 2,
ABORT
Internal error
7, 11
1. Retry the command at 1-minute intervals up to 3 times
2. Escalate if the problem persists.
1005
ABORT
Test configuration is incorrect.
1. Verity PPP link is in-service (status clan-port UUCSSpp or status link n).
2. Repeat the test.
3. Escalate if the problem persists.
1124
ABORT
ppp link is not enabled.
1. Verify that the ppp link is enabled (status port UUCSSpp, status link n, or
2. If the link is not enabled, enable the link (change data-module).
3. Repeat the test.
4. Escalate if the problem persists.
1125
ABORT
PPP link not in service.
1. Verify whether ppp link is in service (status port UUCSSpp or status
2. If the ppp link is not in service, release the link (release link n or release
3. Repeat the test.
4. Escalate if the problem persists.
2000
ABORT
Response to the test was not received from the C-LAN circuit pack within the
allowable time period.
1. If this result occurs repeatedly, attempt to reset the circuit pack if the other
2. If this result occurs again, replace the circuit pack.
2012
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
2. Escalate if the problem persists.
555-233-142
display data-module).
link n).
port UUCSSpp).
ports on the board are idle (amber LED is off). Reset the circuit pack
(busyout board UUCSS, reset board UUCSS, and release board
UUCSS).
Continued on next page
Issue 1 May 2002
8-971