Maintenance Object Repair Procedure
h. This error, when reported with Aux data in the range of 4352 to 4358,
indicates that the circuit pack has reported an on-board hardware failure.
The circuit pack will continuously test the hardware and report the results
approximately every 10 minutes. If the hardware problem is resolved, the
"leaky bucket" strategy should clear the alarm in approximately 30 minutes.
However, if the alarm does NOT clear in 30 minutes, then the circuit pack
should be replaced.
i. This error can be ignored, but look for other errors on this circuit pack.
j. This error is not service-affecting and no action is required.
k. This error indicates that no ringing current is detected. Run Test #51,
Ringing Application test, and follow the procedures for Test #51. This error
is only applicable to Analog Line circuit packs.
l. The hyperactive circuit pack is out-of-service and may exhibit one or more
of the following symptoms:
1. The common circuit pack level tests such as Test #51 and/or
2. The tests run on the ports of this circuit pack are returning with a
3. A busyout/release of the circuit pack has no effect on test results.
4. A list configuration command shows that the circuit pack and ports
If the XXX-BD is not a TN754 Digital Line Circuit Pack (DIG-BD), and if this
error happens again within 15 minutes, then replace the circuit pack. If the
XXX-BD is a TN754 Digital Line Circuit Pack (DIG-BD), then check the
alarm level. If the alarm level is a WARNING, this indicates that users are
probably causing the hyperactivity by playing with their digital stations. If
the circuit pack is really hyperactive then this alarm will be upgraded to a
MINOR alarm within 1 hour. If the alarm level is a MINOR alarm, then
replace the circuit pack.
m. This error indicates that no neon current is detected. Run test board
UUCSS short and follow the procedures for Test #220. This error is only
applicable to TN769 and TN746 Analog Line circuit packs.
n. This error is not service-affecting and no action is required.
o. Error type 3999 indicates that the circuit pack sent a large number of
control channel messages to the switch within a short period of time. If
error type 1538 is also present, then the circuit pack was taken
out-of-service due to hyperactivity. If error type 1538 is absent, then the
circuit pack was not taken out-of-service, but it has generated 50% of the
messages necessary to be considered hyperactive. This may be
completely normal during heavy traffic periods. However, if this error type
is logged when the circuit pack is being lightly used, it may indicate a
problem with the circuit pack or the equipment attached to it.
8-1380
Issue 1 May 2002
Test #220 are aborting with error code 2000.