RMC-ENV (Power/Fan Sensors)
(The fan and power lead is an O-ring of every cabinet's status lead.) Since
an error condition on a fan's or power supply's output could be the result of
a temporary overload (e.g., during board insertion) or caused by the
equipment's location (e.g., fan blockage), a single event may be an
anomaly that eventually clears. However, a repeating condition causes a
major alarm.
On-Demand Tests: Descriptions and Error Codes
Always investigate tests in the order presented in the following table. For
example, by clearing error codes associated with the RMC Power/Fan Query test,
you may also clear errors generated from other tests in the testing sequence.
Test descriptions and recommended maintenance procedures follow for every
error that can occur during on-demand testing.
Table 8-434. On-Demand Tests for Cabinet Sensors
Order of Investigation
RMC Power/Fan Query test (#77)
Analog Ring Generator Initialization test (#117) (a)
Analog Ring Generator Query test (#118) (b)
1.
D = Destructive; ND = Nondestructive
Notes:
a. Refer to
for a description of this test.
b. Refer to
description of this test.
555-233-142
''Analog Ring Generator Initialization Test (#117)'' on page 8-1010
''Analog Ring Generator Query Test (#118)'' on page 8-1011
Short Test
Long Test
Sequence
Sequence
X
X
X
X
X
X
Issue 1 May 2002
1
D/ND
ND
ND
ND
for a
8-1015