Maintenance Object Repair Procedure
Table 8-381. Test #175 Data Module Internal Loop-Around Test
Error
Test
Code
Result
Description / Recommendation
1000
ABORT
System resources required to run this test are not available. The port may be
in use on a valid call. Use status data-module to determine when the port is
available for testing.
1. Retry the command at 1-minute intervals up to 5 times.
1005
ABORT
Loop around testing is not enabled on the data module administration form.
1. Set
1042
ABORT
The port under test is a TTI port and thus has only default translations and no
assigned extension. The test requires an extension assigned to the port being
tested.
1. If there is a need to execute the test on this particular port, then you must
1180
ABORT
A Maintenance/Test circuit pack digital port is not available to carry out the test.
1. Check to see if the Maintenance/Test digital ports are present (use the list
2. If the digital ports (02 and 03) on the M/T-BD are absent, see
3. If the digital ports are present, try the command again at 1-minute intervals
1181
ABORT
No time-slots available to connect digital ports for the test.
1. Try the command again at 1-minute intervals up to 5 times.
1182
ABORT
Internal system error. Failed to connect the digital ports with time-slots.
1. Retry the command at 1-minute intervals up to 5 times.
1340
ABORT
No Maintenance/Test digital port is currently available to perform this test.
1. Use list config to determine whether any Maintenance/Test digital ports
2. Look for M/T-DIG errors in the Error Log. If present, see
3. If the ports are present and no errors are logged against them, retry the
4. If the test continues to abort, replace the Maintenance/Test circuit pack.
8-898
Issue 1 May 2002
Loop-Around Test
form.
fully administer the port so that is has an assigned extension.
config board command and look for ports 02 and 03).
(Maintenance/Test Digital
up to 5 times.
(ports 02 and 03 on the Maintenance/Test circuit pack) are present in the
system. Because at least one Maintenance/Test circuit pack must always
be present in the PPN of any G3r system, there should be at least two such
ports present. If the ports are present, proceed to step 2. Otherwise,
determine why no ports appear in the list config display. See
(Maintenance/Test Digital Port)''
Pack)''.
(Maintenance/Test Digital
command at 1-minute intervals up to 5 times.
field to y on the data module administration
Port)''.
and
''M/T-BD (Maintenance/Test Circuit
Port)''.
Continued on next page
''M/T-DIG
''M/T-DIG
''M/T-DIG
555-233-142