Avaya S8700 Maintenance Manual page 490

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance Object Repair Procedure
Table 8-504. Test #46 Clock Health Inquiry Test
Error
Test
Code
Result
Description / Recommendation
ABORT
Internal system error.
Retry the command at 11-minute intervals up to 5 times.
none
FAIL
This IPSI circuit pack had an apparent loss of clock. One or more of error types
2049, 2305, 3834, 3857, 3858, and 3872 will appear in the error log. Correct
the problem according to the appropriate error log entries.
Once this test fails for an IPSI Tone-Clock, the only way to make it pass (and to
retire the associated alarm) is to repair the problem, to execute the busy ipsi
command, and then issue the release ipsi command against the indicated IPSI
circuit pack.
1
FAIL
This IPSI circuit pack is suspect of having a clock at the edge of its specified
frequency.
Replace the IPSI circuit pack identified in the error log. See
IPSI Circuit Pack'' on page
PASS
This IPSI circuit pack has not reported a loss of clock.
8-1186
Issue 1 May 2002
8-1177.
''Replacing the
Continued on next page