Avaya S8700 Maintenance Manual page 475

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

TIE-TRK (Analog Tie Trunk)
Table 8-498. Test #844-848 Transmission Test — Continued
Error
Test
Code
Result
Description / Recommendation
1947
ABORT
Noise with tone self check failed.
1. Test the TN771 circuit packs.
2000
ABORT
The test timed out while waiting for a response from the TN771 circuit pack.
1. Retry the command at 1-minute intervals up to 5 times.
2012
ABORT
An internal software error occurred.
1. Retry the command at 1-minute intervals up to 5 times.
2053
ABORT
The test call could not be established, but explanatory information is
unavailable.
1. Retry the command at 1-minute intervals up to 5 times.
2056
ABORT
An error occurred while trying to obtain results from the TN771 circuit pack.
1. Test the TN771 circuit packs.
FAIL
Measured transmission performance was in the unacceptable range as
administered on the trunk group form. Retrieve a measurement report via the
list testcalls command. Make sure that ATMS thresholds are set properly on
page 4 of the trunk group form. Besides the facility, test failures can be caused
by faulty test lines or switch paths. If the measurements point to a facility
problem, report the results to the trunk vendor.
8000
FAIL
Measured transmission performance was in the marginal range as
administered on the trunk group form. This generally means that the trunk is
usable but has an undesirable amount of noise or loss. If the user does not
report unacceptable effects, it may not be necessary to take any action.
Retrieve a measurement report via the list testcalls command. Make sure
that ATMS thresholds are set properly on page 4 of the trunk group form.
555-233-142
Continued on next page
Issue 1 May 2002
8-1171

Advertisement

Table of Contents
loading

Table of Contents