Maintenance Object Repair Procedure
Digital Port Loop-Around Test (#13)
This test is a modification of the Voice and Control Channel Local Loop test used
by Digital Station (DIG-LINE) maintenance. This test does not perform the control
channel and secondary information channel loop around tests as described for
DIG-LINE, as these data paths do not exist for the Maintenance/Test digital port.
The primary information channel is tested by first looping back the data channel
onto the TDM bus, and then sending a digital count from the Tone-Clock circuit
pack and receiving the same digital count with a general-purpose tone detector. A
conference test is done next for the primary information channel. This is the same
test as Conference test (#6).
Only one value (Pass, Fail, or Abort) is generated as a result of the two tests. If
either fails or aborts, the sequence is stopped.
Table 8-358. Test #13 Digital Port Loop-Around Test
Error
Test
Code
Result
Description / Recommendation
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
1000
ABORT
The port is use on a valid ISDN-PRI test call. Use the list isdn-testcall
command to determine which call is using the port (from the M/T Port column).
Either wait for the test call to complete (as indicated in the
Duration
isdn-testcall grp/mem command, where grp/mem is determined from the
B-channel
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort and the port is idle, escalate the problem.
1001
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
1002
ABORT
The system could not allocate time slots for the test. The system may be under
heavy traffic conditions, or it may have time slots out-of-service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
2. If the test continues to abort, escalate the problem.