VC-BD
Reset the circuit pack by executing the busyout board UUCSS, reset
board UUCSS, and release board UUCSS commands. When it is reset,
the circuit pack executes a set of tests to detect the presence of any of the
above faults. The detection of one these errors during initialization causes
the circuit pack to lock-up and appear insane to the system. See the repair
procedures in footnote (a) for error type 1.
e. The circuit pack detects a program logic error. While no action is required,
this error may lead to errors of other types being reported against this
circuit pack.
f. The circuit pack cannot update NPE memory and read it back. This error
type can be ignored, but it may lead to other error types being reported
against this circuit pack.
g. A critical hardware failure has been detected on the circuit pack. Use
busyout board UUCSS, reset board UUCSS, followed by release board
UUCSS. If Test #53 passes, the on-board circuitry is healthy. Use test
board UUCSS long clear to retire the alarm. If Test #53 fails, replace the
circuit pack.
h. The circuit pack detected a critical hardware failure. Reset the circuit pack
by issuing the busyout board UUCSS, reset board UUCSS, and release
board UUCSS commands. If the Circuit Pack Restart test (#594) passes,
then the on-board circuitry is healthy. Retire the alarm by issuing the test
board UUCSS long clear command. If the Circuit Pack Restart test
(#594) fails, replace the circuit pack.
The reported error types correspond to the following detected errors:
Error
1293
1294
i. The circuit pack is hyperactive — it is flooding the switch with messages
sent over the control channel. The circuit pack is taken out of service when
a threshold number of these errors is reported to the switch. Clear the
alarm by using busyout board UUCSS, reset board UUCSS, test board
UUCSS long clear, and release board UUCSS. If the error recurs within
10 minutes, then replace the circuit pack.
555-233-142
Description
On-board auxiliary processor insane
Internal memory access error
Issue 1 May 2002