Maintenance Object Repair Procedure
Error Log Entries and Test to Clear Values
Table 8-574. Common Port Circuit Pack Maintenance Error Log Entries
Error
Aux
Type
Data
Associated Test
1
0
0
Any
1 (a)
0
Circuit pack removed or
SAKI Sanity test (#53)
18 (b)
0
busyout board UUCSS
23(c)
0
None
36 (d)
4368
none
125 (e)
None
217 (f)
0
None
257
65535
Control Channel test
(#52)
267 (f)
0
None
513 (h)
Any
None
769 (i)
4358
None
1025 (j)
4363
NPE Audit test (#50)
1281 (k)
Ringing Application test
(#51)
1538 (l)
Any
None
1793 (m)
Neon test (#220)
3840 (n)
Any
None
3999 (o)
Any
None
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
8-1378
Issue 1 May 2002
Alarm
On/Off
Level
Board
Any
Any
MINOR
ON
WARNING
OFF
WARNING
OFF
MINOR
ON
WARNING
ON
MINOR
ON
WARNING
ON
MINOR
ON
MINOR
ON
WARNING
ON
MINOR
MINOR
ON
Test to Clear Value
test board UUCSS sh r 1
release board UUCSS
test board UUCSS sh r
20
test board UUCSS sh
test board UUCSS l r 20
test board UUCSS r 2
test board UUCSS r 2
555-233-142