Avaya S8700 Maintenance Manual page 72

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance Object Repair Procedure
Table 8-329. Test #6 NPE Crosstalk Test — Continued
Error
Test
Code
Result
Description / Recommendation
1018
ABORT
Test disabled via administration. This only applies to analog stations. The
default for this field is y, so you may want to determine why it has been turned
off on this station.
1. To enable the test for the particular analog station being tested, enter the
2000
ABORT
Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2020
ABORT
The test did not run due to an already existing error on the specific port or a
more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit pack
2100
ABORT
System resources required to run this test are not available. This could be due
to a failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times.
Any
FAIL
This test can fail due to on-board or off-board problems. Off-board problems of
concern include RMC-ENV faults, TDM-BUS faults, and faults associated with
the tone detectors/tone generators. Clear every off-board problem before
replacing the board. Keep in mind that a TDM-BUS problem is usually the
result of a faulty board connected to the backplane or bent pins on the
backplane.
1. Resolve any RMC-ENV errors.
2. Resolve any TDM-BUS errors.
3. Resolve any TONE-BD and/or TONE-PT errors.
4. Test the board when the faults from steps 1, 2, and 3 are cleared. Replace
8-768
Issue 1 May 2002
change station extension command and change the
'Station' form from 'n' to 'y.'
and attempt to diagnose the already existing error.
the board only if the test fails.
Test
field on the
Continued on next page
555-233-142

Advertisement

Table of Contents
loading