Avaya S8700 Maintenance Manual page 611

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

UDS1-BD (UDS1 Interface Circuit Pack)
Table 8-542. Test #1216 End Loopback/Span Test — Continued
Error
Test
Code
Result
Description / Recommendation
PASS
The active long-duration loopback or span test on the UDS1-BD circuit pack
was successfully terminated.
0
NO
The test could not relate the internal ID to the port (no board). This could be
BOARD
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Verify that the board's translations are correct. Execute the add ds1
2. If the board was already administered correctly, check the error log to
3. If the board was found to be correctly inserted in step 1, then issue the
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.
555-233-142
UUCSS command to administer the UDS1 interface if it is not already
administered.
determine whether the board is hyperactive. If so, the board was shut
down. Reseating the board will re-initialize it.
busyout board command.
Continued on next page
Issue 1 May 2002
8-1307

Advertisement

Table of Contents
loading

Table of Contents