Avaya S8700 Maintenance Manual page 674

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance Object Repair Procedure
Technician-Demand Tests: Descriptions and Error
Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. For example, by clearing error codes associated with the
NPE Crosstalk test (#6), you may also clear errors generated from other tests in
the testing sequence.
Order of Investigation
NPE Crosstalk test (#6)
Conference Circuit test (#7)
Port Audit and Update test (#36)
1.
D = Destructive; ND = Nondestructive
NPE Crosstalk Test (#6)
The NPE Crosstalk test verifies that this port's NPE channel talks on the selected
time slot, and does not cross over to time slots reserved for other connections. If
the NPE is not working correctly, 1-way and noisy connections may be observed.
This test is usually part of a port's long test sequence and takes 20 to 30 seconds
to complete
Table 8-570. Test #6 NPE Crosstalk Test
Error
Test
Code
Result
Description / Recommendation
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test are not available. The port may be
in use on a valid call. Use the status access-endpoint extension or command
to determine when the port is available for testing.
1. Retry the command at 1-minute intervals up to 5 times.
1001
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
8-1370
Issue 1 May 2002
Short Test
Long Test
Sequence
Sequence
X
X
X
X
Continued on next page
1
D/ND
ND
ND
ND
555-233-142

Advertisement

Table of Contents
loading

Table of Contents