Maintenance Object Repair Procedure
Table 8-380. Test #17 Data Module Audits Test — Continued
Error
Test
Code
Result
Description / Recommendation
5
ABORT
Ringer update aborted (data module not in the in-service state)
1. Verify that the data module is powered (power LED on).
2. Make sure data module is connected to the building wiring, check for faulty
3. Retry the command at 1-minute intervals up to 5 times.
4. Replace the Data Module and repeat the test.
5. If the test continues to abort, replace the Digital Line circuit pack and repeat
6
ABORT
Data module translation update aborted.
1. Verify the data module is connected to the PBX.
2. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1392
ABORT
This port is currently a TTI port and the test will not execute on it.
1. Verify that the port is a TTI port using either the display port command (the
2. If either list config or display port indicate that the port is not a TTI port,
2000
ABORT
Response to the test was not received within the allowable time period.
FAIL
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS
Data Module audits passed. This digital port circuit pack is functioning properly.
1. If complaints still exist, investigate by using other port tests and by
Data Module Internal Loop-Around Test (#175)
This test verifies that a data message can be sent from the PBX, through the
building wiring, through an internal loop-around path in the data module, and back
to the PBX. This path is illustrated below.
8-896
Issue 1 May 2002
wiring, check for faulty data module.
the test.
display shows that the port is a TTI port) or the list config command (the
display shows a
for the port).
t
escalate the problem. If both commands indicate that the port is a TTI port,
the abort is correct, and no action is necessary.
examining the data module options, wiring, and connections.