Npe Connection Audit Test (#50) - Avaya S8700 Maintenance Manual

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance Object Repair Procedure

NPE Connection Audit Test (#50)

The system sends the circuit pack's on-board microprocessor a message to
update the network-connectivity translation for its SCOTCH-NPE chip.
Table 8-522. Test #50 NPE Connection Audit Test
Error
Test
Code
Result
Description / Recommendation
None,
ABORT
System resources required for this test are not available.
2100
1. Retry the command at 1-minute intervals up to 5 times.
1019
ABORT
The test aborted because a test was already running on the port.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS
The circuit pack's SCOTCH-NPE chip has been updated with its translation.
0
NO
The test could not relate the internal ID to the port (no board). This could be
BOARD
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Verify that the board's translations are correct. Execute the add ds1
2. If the board was already administered correctly, check the error log to
3. If the board was found to be correctly inserted in step 1, then issue the
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.
8-1236
Issue 1 May 2002
UUCSS command to administer the UDS1 interface if it is not already
administered.
determine whether the board is hyperactive. If this is the case, the board is
shut down. Reseating the board will re-initialize it.
busyout board command.
Continued on next page
555-233-142