Copy Pair Status Transitions For Delta Resync Pairs - HP XP P9500 Software User's Manual

Hp p9000 business continuity manager user guide
Hide thumbs Also See for XP P9500:
Table of Contents

Advertisement

3.
Transfer the copy group definition file to the local site and the remote site.
If you are not using Business Continuity Manager at the remote site, you do not need to transfer
the copy group definition file to the remote site.
4.
Create copy pairs for the Cnt Ac-S Z copy group and the Cnt Ac-J Z copy group.
5.
Use the YKEWAIT command with the GOTO(DUPLEX) parameter specified to continue
monitoring until the status of all copy pairs has changed to DUPLEX.
6.
Execute the YKQUERY command on the Cnt Ac-S copy group between the primary site and
the local site to confirm that the following conditions exist:
The number of Cnt Ac-S copy pairs is equal to the number of delta resync pairs to be
created.
The copy pair status is DUPLEX.
The copy direction is from the primary site to the local site.
7.
Execute the YKQUERY command on the Cnt Ac-J Z copy group between the primary site and
the remote site to confirm that the following conditions exist:
The number of Cnt Ac-J Z pairs is equal to the number of Cnt Ac-S Z copy pairs and is
also equal to the number of delta resync pairs to be created.
The copy pair status is DUPLEX.
The copy direction is from the primary site to the remote site.
8.
On the Cnt Ac-J Z copy group for the delta resync function, execute the delta resync pair
creation command (the YKMAKE command with the HOLD parameter specified).
9.
Monitor the Cnt Ac-J Z copy group for the delta resync function (by executing the YKEWAIT
command with the GOTO(HOLD) parameter specified) until all pairs have entered the HOLD
status.
For the action to be taken if the YKEWAIT command abnormally terminates, see
be Taken When the Delta Resync Function Cannot be Set Up or Operated Successfully"
(page
340).
10. Set up a delta resync control path between storage systems by using Remote Web Console.

Copy pair status transitions for Delta Resync pairs

Figure 80 (page 175)
If YKRESYNC DELTAJNL is executed for a copy pair in the HOLD status, such a copy pair first
changes to the PENDING status just as when YKRESYNC ALLJNL is executed, and then changes
to the DUPLEX status.
174
Configuration Definitions
shows copy pair status transitions for delta resync pairs.
"Actions to

Advertisement

Table of Contents
loading

This manual is also suitable for:

P9000 for business continuity manager 6.6.1

Table of Contents