Acquiring Volume Information (Preparations); Performing A Local Scan To Acquire Volume Information; Performing An Ng Scan (On A Non-Gen'ed Volume) To Acquire Device Configuration Information; Preparing The Hardware (Ng Scan) - HP XP P9500 Software User's Manual

Hp p9000 business continuity manager user guide
Hide thumbs Also See for XP P9500:
Table of Contents

Advertisement

NOTE:
For configurations where the same storage system is connected from hosts at different
sites, the same volume might have different device numbers. Therefore, you cannot create a disk
configuration definition file on a site to transfer to the other sites for use. For this reason, perform
a local scan for P-VOLs and S-VOLs at each site, and then create a disk configuration definition
file.

Acquiring volume information (preparations)

To acquire device configuration information about the volumes on the storage systems, perform
the following scans:
Local scan
NG Scan on a local or remote site
Remote scan

Performing a local scan to acquire volume information

Perform a local scan at the primary site to acquire information about a storage system and
automatically create a disk configuration definition file. Initiate the local scan by either executing
the YKSCAN command or by initiating it from the ISPF panel.
To acquire storage system information at the secondary site, perform a local scan at that site (using
the same file prefix you used for the local scan at the primary site), transfer the resulting disk
configuration definition file to the primary site and store the information in the disk configuration
definition file on the primary site.
For background information about the file prefix, see
(page
102).
To see the procedures for initiating these operations from the ISPF panels, see
information" (page
NOTE:
When performing a scan, Business Continuity Manager automatically determines the
model of the storage system and returns the information.
Performing an NG Scan (on a Non-Gen'ed Volume) to acquire device configuration
information
This section describes how to prepare for an NG scan to acquire device configuration information
of local Non Gen'ed volumes.

Preparing the hardware (NG Scan)

Table 26 (page 106)
settings for executing an NG scan.
Table 26 Prerequisite hardware (NG Scan)
Item
Host
Storage system
Link between storage systems (physical
path)
106 Preparing to use Business Continuity Manager
430).
lists the prerequisite hardware and
Description
One unit for the primary or remote site
One or more XP12000/XP10000,
XP24000/XP20000, or P9500 Disk
Array
Required for when Cnt-Ac J Z or BC Z
if a remote site is used
"Setting a prefix for configuration files"
Table 27 (page 107)
Remarks
"Acquiring volume
lists the storage system

Advertisement

Table of Contents
loading

This manual is also suitable for:

P9000 for business continuity manager 6.6.1

Table of Contents