HP XP P9500 Software User's Manual page 514

Hp p9000 business continuity manager user guide
Hide thumbs Also See for XP P9500:
Table of Contents

Advertisement

Table 88 Overview of Business Continuity Manager Monitor parameter files
File name
YKMONOPT
YKMONCG
"Behavior of Business Continuity Manager Monitor" (page 516)
Manager Monitor works when the Business Continuity Manager Monitor parameter files are
specified as shown in
514
Automatic operation using BCM Monitor
Parameter type
Parameter name
None
CYCLETIME
Cycle time
WAITTIMEOUT
Default timeout value
MSGLEVEL
Message level
ONACTIONERROR
Default error action value
Copy group
CGID (Copy group ID)
parameter
CGPREFIX (Prefix)
CGDAD (Host device
address domain ID)
CGROUTE (Route list ID)
CGMONSTAT
Monitoring status
CGSTARTUPSTATUS
Startup status, startup
action
Action
STATUS
parameter
Target status
ACTION
Action, error action
"Example of Business Continuity Manager Monitor parameter files" (page
Description
Specifies the interval for monitoring (obtaining the
statuses of) copy groups
Specifies the default timeout value for the CLI commands
specified in the YKMONCG file
Specifies the level of messages to be output
Specifies the default value of the error actions specified
in the YKMONCG file
Specifies the following copy groups and their
environments
Copy groups to monitor
Copy groups for which actions will be executed
Copy groups for which operator commands will be
issued
Specifies whether to monitor the copy group
ACTIVE: Monitors the copy group. If the copy group
changes to the specified target status, the designated
actions are executed.
INACTIVE: Does not monitor the copy group.
Specify this parameter if you want to perform actions
for the copy group or display information about the
copy group by using the MODIFY REPORT
command without monitoring the status. You can
change the value to ACTIVE by using the MODIFY
SET command.
Startup status: Specifies the status of the copy group
for when Business Continuity Manager Monitor starts
Startup action: Specifies the action that is executed
when Business Continuity Manager Monitor starts
but the monitored copy group is not in the specified
startup status
Specifies the status of the copy group for which the
action is to be executed
Action: Specifies the action to perform when the
copy group is in the target status
Error action: Specifies the action to perform when
the action that was executed results in an error
describes how Business Continuity
515).

Advertisement

Table of Contents
loading

This manual is also suitable for:

P9000 for business continuity manager 6.6.1

Table of Contents