The Monitoring Status Of A Copy Group; Putting Business Continuity Manager Monitor To Sleep; Stop Point; Starting And Stopping The Business Continuity Manager Monitor - HP XP P9500 Software User's Manual

Hp p9000 business continuity manager user guide
Hide thumbs Also See for XP P9500:
Table of Contents

Advertisement

The monitoring status of a copy group

Business Continuity Manager Monitor can monitor one copy group at a time. In the CGMONSTAT
parameter of the YKMONCG file, if you specify ACTIVE for two or more copy groups, the copy
group for which ACTIVE is specified first will be monitored. If the monitoring status of the currently
monitored copy group changes to INACTIVE, the next copy group for which ACTIVE is specified
will be monitored.
After Business Continuity Manager Monitor starts, the monitoring status specified in the CGMONSTAT
parameter is changed in the cases shown below. You can check the changed monitoring status
by using the MODIFY DISPLAY command.
When changing the monitoring status from ACTIVE to INACTIVE by executing the MODIFY
SET command with MONITOR=STOP specified
When changing the monitoring status from INACTIVE to ACTIVE by executing the MODIFY
SET command with MONITOR=START specified
When the monitoring status is changed from ACTIVE to INACTIVE by a startup action, an
action, or an error action

Putting Business Continuity Manager Monitor to sleep

You can put Business Continuity Manager Monitor to sleep by executing the MODIFY SLEEP
command or by performing a PAUSE action. This status is cleared when the specified sleep duration
has elapsed, or when Business Continuity Manager Monitor accepts the MODIFY WAKEUP
command.

Stop point

You can specify a label name for an action in order to stop or put Business Continuity Manager
Monitor to sleep at a particular point. In
parameter files" (page
Business Continuity Manager Monitor is processing an action before where the
ACTION=STOPPOINT(LABEL1) at (2) is located, Business Continuity Manager Monitor will
stop after all the actions up to that point have finished. If Business Continuity Manager Monitor is
processing an action after where ACTION=STOPPOINT(LABEL1) is specified, Business Continuity
Manager Monitor will not stop during that cycle. Business Continuity Manager Monitor will stop
when the process reaches ACTION=STOPPOINT(LABEL1) in subsequent cycles.

Starting and stopping the Business Continuity Manager Monitor

This section describes the commands for starting, stopping, and forcibly stopping Business Continuity
Manager Monitor. This section also describes the return codes for Business Continuity Manager
Monitor.
For the symbols used in the explanation on the format of commands, see
explanations" (page

Starting Business Continuity Manager Monitor

To start Business Continuity Manager Monitor, use the START command.
Business Continuity Manager Monitor operates according to the information specified in the Business
Continuity Manager Monitor parameter files. You can launch multiple instances of Business Continuity
Manager Monitor at the same time.

Format

START
, cataloged-procedure-for-startup-name[.identification-name]
"Example of Business Continuity Manager Monitor
515), if you input the MODIFY STOP command with LABEL1 specified while
591).
Starting and stopping the Business Continuity Manager Monitor
"Conventions in syntax
517

Advertisement

Table of Contents
loading

This manual is also suitable for:

P9000 for business continuity manager 6.6.1

Table of Contents