Setting The Controller Scsi Id; Changing Other Controller Scsi Settings; Switching Controllers; Testing A Controller - HP Surestore Disk Array 12h - And FC60 Service Manual

Hp surestore e disk array 12h user's and service manual (c5445-90901, september 1999)
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

3. Select Confirm.
4.
Use the View Settings menu to check the rebuild progress.

Setting the Controller SCSI ID

1.
Select the Cntrl Changes from the main menu.
2.
Select SCSI ID.
3.
Select a controller Cntrl X or Cntrl Y.
4.
Select SCSI ID 0 to 15. (Offline takes disk array offline.)
5. Select Reset.
6. Select Confirm.

Changing Other Controller SCSI Settings

1.
Select the Cntrl Changes from the main menu.
2.
Select Unit Attn, Term Power, Parity, WDTR, SDTR, DRR, or VEB.
3.
Select Enable or Disable.
4. Select Confirm.

Switching Controllers

1.
Select the Cntrl Changes from the main menu.
2.
Select Switch Cntrl.
3. Select Reset.
4. Select Confirm.

Testing a Controller

1.
Select the Cntrl Changes from the main menu.
2.
Select Reset Cntrl.
3.
Select a controller Cntrl X or Cntrl Y.
4. Select Reset.
5. Select Confirm.
Operating the Control Panel
Using the Control Panel Buttons
73