Using The Control Panel Buttons; Viewing Array Settings; Creating A Logical Drive; Renumbering A Logical Drive - HP Surestore Disk Array 12h - And FC60 Service Manual

Hp surestore e disk array 12h user's and service manual (c5445-90901, september 1999)
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

Using the Control Panel Buttons

Viewing Array Settings

1.
Select the View Settings from the main menu.
2.
Use + or – to view the current settings.
3.
Select the SCSI values menu to view settings for Unit Attn, Term Power, Parity, WDTR, SDTR, DRR,
and VEB.
4.
Select the Disk State menu to view the state of disks A1 to A6 and B1 to B6.
5. Select the L-Drv State menu to view the capacity of logical drives in the array.

Creating a Logical Drive

1. Select the Logical Drv Changes from the main menu.
2. Select Create Logical Drv.
3.
Select a drive number 0 to 7.
4.
Select a capacity size 100 Megabytes to Maximum.
5. Select Confirm.

Renumbering a Logical Drive

NOTE! Before renumbering a logical drive, you should know the impact this will have on the
operating system. After you renumber a logical drive, make sure you perform the necessary steps
to configure the renumbered logical drive into the operating system.
1. Select the Logical Drv Changes from the main menu.
2.
Select Renumber L-Drv.
3.
Select From drive number 0 to 7.
4.
Select To drive number 0 to 7.
5. Select Confirm.
Operating the Control Panel
Using the Control Panel Buttons
71