Event
Event Name
Number
(DEC/hex)
Secondary
215/0xd7
Controller
Failed With
Memory Error
Secondary
216/0xd8
Controller
Failed,
Communication
ECC Errors
Secondary
217/0xd9
Controller
Failed To
Enable RAM
Mirroring
Event
Predictive
Logged
Maintenance
Implication
Y
Ignore if
SIMM
configurations
do not match
See
Y
accompanying
errors
Y
See
accompanying
errors
Event Code Descriptions
Suspected
Description
Components
SIMM
A controller was discovered to
Controller
be bad during power on.
Backplane
Specifically, the secondary
controller appears to have
failed due to some memory
error or violation. If the
memory contents on each
board does not match (in
number), this error can occur.
Additionally, if a memory
component fails, it will cause
this error.
This will occur if a different
number of SIMMs are used on
each controller.
None
A controller was discovered to
be bad during power on.
Specifically, the secondary
controller appears to have
failed due to the inability for
the communication area of
NVRAM to be cleared of ECC
errors.
None
A controller was discovered to
be bad during power on.
Specifically, the secondary
controller appears to have
failed due to the mirror not
coming to an up state within 1
second of power on.
Troubleshooting