Error Message
Log Disk
A requested mark on the log disk has failed.
Not Marked
L-Drv Not
The SCSI command to Delete Volume failed.
Deleted
L-Drv Not
The SCSI command to Renumber Logical Drive
Renumbered
failed.
Mismatched
The two controllers installed have different
CNTLR
personality profiles. Unique controller
personalities are created for different vendors.
These personalities are incompatible with one
another.
Mismatched
The two controllers installed are from different
CNTLR
product families.
No Address
No data maps are available for the controller
Table
module; data was lost due to missing disk
modules or no NVRAM image to match disk
modules.
No Code
The firmware download was unsuccessful; there
is insufficient processor firmware to operate the
controller.
No L-Drv
The SCSI command to Create Logical Drive
Created
failed.
No Quorum
Less than half of the disk modules in the disk set
are present.
No Resources
A front panel request is in contention with user
I/O.
Explanation
Control Panel Error Messages
Action
Retry. If error continues, return log disk for a
replacement.
Call the support line.
Call the support line.
Do not use controllers from different vendors
in the same disk array enclosure. Remove the
incompatible controller and replace it with a
controller from the correct vendor. Call the
support line.
Do not use controllers from different product
families (different vendors) in the same disk
array enclosure. Call the support line.
If your disk array is a boot device, you may
have to recover the maps by using the front
panel command called "Recover" under the
"Cntrl Changes" menu.
The arrayrecover utility is described in detail
in the System Administrator's Guide, which is
shipped with each disk array.
Attempt downloading firmware upgrade again.
Call the support line.
The array diagnostics may have been running
when someone accessed the control panel, or
the array is malfunctioning. Call the support
line.
Install missing disk modules or format the
array. Caution: Formatting the array
requires deleting logical drives (LUNs), and
deleting LUNs erases all data!
Retry the front panel operation until you are
successful.
Troubleshooting
129

Advertisement

Table of Contents