Removal and Replacement
Backplane Assembly–HP-qualified personnel only
Table 15. SCSI Bus Reset Switch Functions
Switch Number
SCSI Bus
Bus Y
Switch Name
Power Detect
SCSI Bus Default
Switch Setting
(Disabled)
Switch Function
When the Bus Y
Power Detect Switch
When Enabled
is enabled, the disk
array controller
generates a SCSI Bus
Reset on Bus Y
whenever power is
applied or removed.
When the Bus Y
Switch Function
When Disabled
Power Detect Switch
is disabled (default),
the disk array
controller will not
generate a SCSI Bus
Reset on Bus Y
whenever power is
applied or removed.
198
1
2
Bus Y
Controller Detect
OFF
ON
(Enabled)
When the Bus Y
Controller Detect
Switch is enabled
(default), the disk
array controller
generates a SCSI Bus
Reset on Bus Y
whenever disk array
controller Y is
inserted or removed.
When the Bus Y
Controller Detect
Switch is disabled,
the disk array
controller will not
generate a SCSI Bus
Reset on Bus Y
whenever disk array
controller Y is
inserted or removed.
3
Bus X
Power Detect
Controller Detect
OFF
(Disabled)
(Enabled)
When the Bus X
When the Bus X
Power Detect Switch
Controller Detect
is enabled, the disk
Switch is enabled
array controller
(default), the disk
generates a SCSI Bus
array controller
Reset on Bus X
generates a SCSI Bus
whenever power is
Reset on Bus X
applied or removed.
whenever disk array
controller X is
inserted or removed.
When the Bus X
When the Bus X
Power Detect Switch
Controller Detect
is disabled (default),
Switch is disabled,
the disk array
the disk array
controller will not
controller will not
generate a SCSI Bus
generate a SCSI Bus
Reset on Bus X
Reset on Bus X
whenever power is
whenever disk array
applied or removed.
controller X is
inserted or removed.
4
Bus X
ON

Advertisement