HP Surestore Disk Array 12h - And FC60 Service Manual page 160

Hp surestore e disk array 12h user's and service manual (c5445-90901, september 1999)
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

Troubleshooting
Event Code Descriptions
Event
Event Name
Number
(DEC/hex)
Cancel Rebuild
141/0x8d
Complete
Disk Drive
142/0x8e
Table Overflow
160
Event
Predictive
Logged
Maintenance
Implication
Y
Ignore -
Operator or
Host Activity
Ignore -
Y
Operator
activity
Suspected
Description
Components
None
The cancellation of a rebuild
has completed.
None
The controller is capable of
retaining information about 16
drives. Disk drives that are
removed from the array and
enter the missing drive list are
included in this count. If the
total number of disk installed
in the array plus any missing
drives ever exceeds 16, this
condition is logged. The disk
array always generates a data
unavailable warning before
this condition is reached.
Once the 16 disk limit is
reached, the controller will not
recognize any additional
drives installed in the array.
Because the controller cannot
add the new disks to the drive
list, the status light on the
newly installed disk will
remain amber.
To correct his problem and
maintain data integrity, find
and reinstall the missing disks.
If the data on the disk array is
not critical, the disk array can
be reformatted with the new
disks. .