Event
Event Name
Number
(DEC/hex)
Replace
203/0xcb
Batteries
Cache Shrink
204/0xcc
Attempted After
Shutdown
Warning
Controller
205/0xcd
Failed
SIMM Failed
206/0xce
Extended
207/0xcf
Drive
Installation
Event
Event
Predictive
Logged
Maintenance
Implication
Y
Single
Occurrence
Ignore - see
Y
errors during
shutdown
Y
Ignore if
corrected by
reset or
power cycle
Y
Single
Occurrence
Y
Ignore unless
no operator
activity
Event Code Descriptions
Suspected
Description
Components
Batteries
The batteries have failed a
discharge test or have dropped
Controller
below an acceptable voltage
level. Both batteries should be
replaced.
None
The amount of cache on the
controller has shrunk due to
SIMM failure or removal.
This happened with valid
writes still in cache, and all
the writes no longer fit in the
reduced amount of cache.
Controller
During power on, a bad
controller was detected. This
may result if the controller has
difficulty establishing
communication. Ignore if
recovered by power cycle or
reset.
SIMM
A SIMM was discovered to be
Controller
bad during power on.
Disk Drive
An internal SCSI channel is
being held reset longer than
Controller
expected. Typically caused by
Internal SCSI
a partially-installed drive
Bus
module, a failing drive
module, a failing controller, or
a bent pin on a connector.
Troubleshooting