HP Surestore Disk Array 12h - And FC60 Service Manual page 176

Hp surestore e disk array 12h user's and service manual (c5445-90901, september 1999)
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

Troubleshooting
Event Code Descriptions
Event
Event Name
Number
(DEC/hex)
Fan Failed
198/0xc6
Power Supply
199/0xc7
Failed
Power Down
200/0xc8
Due To Fan
Failure
Fan Missing At
201/0xc9
Initialization
Power Down
202/0xca
Due To Missing
Fan
176
Event
Predictive
Logged
Maintenance
Implication
Y
Single
Occurrence
Single
Y
Occurrence
Single
Y
Occurrence
Y
Ignore - See
accompanying
errors.
Y
Single
Occurrence
Suspected
Description
Components
Fan
A fan has failed and should be
Controller
replaced.
Backplane
Power Supply
A power supply has failed and
Controller
should be replaced.
Backplane
Fans
The controller has detected
Controller
that not enough fans are
Backplane
functioning to cool the disk
array properly. As a result, the
controller is shutting off the
power supply to avoid
overheating.
Note: The NVRAM is not
posted to disk, so it is critical
to repair the system quickly.
None
During startup, the controller
detected that a fan had been
removed from the enclosure.
The total length of time a fan
has been missing will be
checked periodically and
when it exceeds
approximately 10 minutes, the
controller will shut off the
power supply.
Fan
The controller is shutting off
Controller
the power supply because a
Backplane
fan has been missing from the
enclosure for too long
(approximately 10 minutes).