HP Surestore Disk Array 12h - And FC60 Service Manual page 178

Hp surestore e disk array 12h user's and service manual (c5445-90901, september 1999)
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

Troubleshooting
Event Code Descriptions
Event
Event Name
Number
(DEC/hex)
Internal SCSI
208/0xd0
Bus State
Event
Uncorrectable
209/0xd1
ECC Error
During
Initialization
178
Event
Predictive
Logged
Maintenance
Implication
Y
Single
Occurrence
Y
More than 1
in 6 months if
no operator
activity
Suspected
Description
Components
Controller
A disk drive responded
incorrectly. The result was an
Disk Drive
internal SCSI bus reset, and a
Internal SCSI
hot-plug recovery sequence to
Bus
regenerate the bus state. The
control panel display may
indicate "verifying drives" as
a result of the internal bus
reset.
The controller experienced an
SIMM
unrecoverable error during
Controller
power on. This is expected in
any of the following
situations:
- The batteries have been fully
discharged.
- The batteries were
disconnected from the
memory
- New SIMM memory was
added
All other situations, this event
represents a true memory
error.