Appendix A. Product Specifications
Environmental Requirements

Altitude Ranges

Operating: 0 to 3,048 m (0 to 10,000 ft)
Nonoperating: 0 to 4,572 m (0 to 15,000 ft)

Vibration

Operating Random Vibration: 0.21 Grms, 5 to 500 Hz
Nonoperating Random Vibration: 2.09 Grms, 5 to 500 Hz
Nonoperating Vibration Sine Sweep: 0.5 G (0 to peak), 5 to 500 Hz

Shock

Operating Shock: 6.35 mm (0.25 in.) tilt drop (independent of weight)

Line Input Requirements

Nominal Voltages: 100-127 Vac, 200-240 Vac
Maximum Input Power: 870 VA (7.3 A @ 120 Vac, 3.8 A @ 230 Vac)
Voltage Range: 88 – 140 Vac, 180 – 269 Vac
Nominal Frequencies: 60 Hz (120 Vac), 50 Hz (230 Vac)
Inclusive Frequency Range: 47 to 66 Hz
Transparent Line Surge: 293 Vac for 0.5 seconds
Recoverable Line Surge: 298 Vac for 0.5 seconds
Line voltage sag: 80.5 Vac for 0.5 seconds
Power Line Dropout: Must not exceed 20 ms