HP Surestore Disk Array 12h - And FC60 Service Manual page 168

Hp surestore e disk array 12h user's and service manual (c5445-90901, september 1999)
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

Troubleshooting
Event Code Descriptions
Event
Event Name
Number
(DEC/hex)
Insufficient
167/0xa7
RAM For Image
Upload
Internal SCSI
168/0xa8
Queuing
Disabled
Internal SCSI
169/0xa9
Disconnects
Disabled
168
Event
Predictive
Logged
Maintenance
Implication
Y
Ignore -
Operator error
or
accompanying
errors
Y
Immediate
Performance
Problem -
Unsupported
Disk
Y
Immediate
Performance
Problem -
Unsupported
Disk
Suspected
Description
Components
None
This errors occurs if a disk set
has been moved from a
controller with more RAM to
a controller with less RAM.
Consequently, the current
RAM configuration is not
large enough to hold the
NVRAM image stored on
disk. More RAM can be added
to the controller to correct this
problem
Disk Drive
This event indicates that the
controller couldn't set the
SCSI configuration settings
for the disk drive correctly.
This could be caused by a
failing disk drive, or the use of
an unsupported disk drive.
Disk Drive
The controller could not
configure the disk drive to
disable disconnects during
data transfer phase. This will
cause the interface driver to
disable disconnects on the
channel, thus causing
degraded drive performance.
This event may also indicate
that the controller could not
enable queuing on this drive
so the interface driver will
disable disconnects on the
channel.
This is typically caused by
using an unsupported disk
drive that the controller cannot
configure properly.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Surestore e disk array 12h

Table of Contents