HP Surestore Disk Array 12h - And FC60 Service Manual page 184

Hp surestore e disk array 12h user's and service manual (c5445-90901, september 1999)
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

Troubleshooting
Event Code Descriptions
Event
Event Name
Number
(DEC/hex)
Disk Format
223/0xdf
Version
Mismatch
Shutdown Due
224/0xe0
To Power
Supply Failure
Recovery from
225/0xe1
battery backed
RAM Loss
Started
184
Event
Predictive
Logged
Maintenance
Implication
Y
NA
Y
Single
Occurrence
Y
Single
Occurrence
Suspected
Description
Components
None
The NVRAM format of the
disks does not match the
format used by the controller.
This event is logged when an
icicle controller attempts to
use disks previously shutdown
by an Ice controller or visa-
versa. The controller cannot
use an NVRAM image in the
incorrect format.
Power
This error code indicates that
Supplies,
the Background Manager
Controller,
(BGM) has discovered that
Backplane
there are not enough good
power supplies to run the
system. The BGM is shutting
down the subsystem to
minimize system operation
with inadequate power. Note:
The NVRAM is posted to
disk.
Controller
This error code indicates that
recovery from a battery
backed RAM loss has been
initiated. The contents of the
NVRAM that is battery
backed up has been lost and
the arrayrecover command has
been initiated. The contents of
the NVRAM has started to be
rebuilt. (This is a feature only
in controller firmware
revisions HP54 and later.)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Surestore e disk array 12h

Table of Contents