Event
Event Name
Number
(DEC/hex)
Not Enough
18/0x12
Space
Command
19/0x13
Illegal In
Current State
Becoming
20/0x14
Ready
Recovered With
21/0x15
Low Level
Retries
Event
Predictive
Logged
Maintenance
Implication
Y
Ignore
NA
N
N
NA
Y
Ignore
Event Code Descriptions
Suspected
Description
Components
None
A write command had to
move data in order to find
enough space to complete.
Errors were encountered
during this process which
prevented the controller from
providing enough space for
the write.
This would typically result
from multiple failing or
missing drives. If disk drives
have been removed, reinstall
them in the array.
None
The requested operation is not
allowed due to the current
state of the disk array. Certain
operations require the disk
array to be in a specific state
for execution. For example,
the disk array must be
shutdown to perform a
download.
None
The disk array has not finished
its initialization.
Disk Drive
After failing the initial I/O,
data was recovered using
Controller
retries. It was necessary to
Internal SCSI
use redundancy to recover the
Bus
data.
Troubleshooting
139

Advertisement

Table of Contents
loading

This manual is also suitable for:

Surestore e disk array 12h

Table of Contents