Troubleshooting
Event Code Descriptions
Event
Event Name
Number
(DEC/hex)
Disk Drive State
50/0x32
Changed During
Add Physical
Drive
51/0x33
Host SCSI
Controller
Parity Error
Host SCSI
52/0x34
Parity Error
146
Event
Predictive
Logged
Maintenance
Implication
N
NA
Single
Y
Occurrence
Y
Single
Occurrence
Suspected
Description
Components
None
During an Add Physical Drive
command the disk drive is
reconfigured for proper
operation with the controller.
If the reconfiguration fails the
first attempt but succeeds the
second, the controller
simulates a hot plug event on
the disk drive to determine the
true status of the disk drive.
The add physical drive
command fails if this
condition is encountered.
The disk drive state should be
reviewed by the host and the
add command reattempted if
appropriate.
Controller
A SCSI DATA-IN phase
received a parity error which
indicates a problem on the
controller, not the SCSI bus.
All retries have been
exhausted.
Controller,
A parity error was detected on
the Host SCSI bus. All retries
Host SCSI
have been exhausted.
Bus
This may be caused by an
improperly configures SCSI
bus. Make sure all cables and
terminators are installed
correctly.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Surestore e disk array 12h

Table of Contents