HP Surestore Disk Array 12h - And FC60 Service Manual page 179

Hp surestore e disk array 12h user's and service manual (c5445-90901, september 1999)
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

Event
Event Name
Number
(DEC/hex)
Correctable
210/0xd2
ECC Error
During
Initialization
Controller
211/0xd3
Failed Local
Address Decode
Test
Controller
212/0xd4
Failed Remote
Address Decode
Test
Event
Predictive
Logged
Maintenance
Implication
Y
More than 1
in 6 months if
no operator
activity
Ignore if
Y
corrected by
reset or power
cycle.
Y
Ignore if
corrected by
reset or power
cycle.
Event Code Descriptions
Suspected
Description
Components
The controller experienced an
SIMM
unrecoverable error during
Controller
power on. This is expected in
any of the following
situations:
- The batteries have been fully
discharged.
- The batteries were
disconnected from the
memory
- New SIMM memory was
added
All other situations, this event
represents a true memory
error.
SIMM
A controller was discovered to
Controller
be bad during power on.
Specifically, the secondary
controller appears to have
failed the request to perform a
local memory decode test or
was unable to establish
communication with the other
controller. This may be
recovered by power cycle or
reset.
SIMM
A controller was discovered to
Controller
be bad during power on.
Backplane
Specifically, the secondary
controller appears to have
failed the request to perform a
remote memory decode test or
was unable to establish
communication with the other
controller. This may be
recovered by power cycle or
reset.
Troubleshooting
179

Advertisement

Table of Contents
loading

This manual is also suitable for:

Surestore e disk array 12h

Table of Contents