Suppressing Single-Controller Warning Messages
When a single controller disk array is powered on for the first time, the control panel may display a
"System Warning" error message, which occurs because only one controller is installed. By default, the
disk array assumes that there should be two controllers installed, and therefore it will generate single-
controller error messages until you suppress them.
If a "System Warning" error message is displayed on the front panel, you must first verify that it is caused
by the detection of a single controller. Use the control panel keys to verify the source of the message by
using the following key sequence:
KEY
CANCEL CANCEL
MENU
–
ENTER
+
To avoid future single-controller warning messages, you can suppress them using the arraymgr ARM
command line utility. The arraymgr utility is described in further detail in the System Administrator's
Guide, which is shipped with each disk array.
DISPLAY
"System Warning"
"Language"
"View Settings"
"System State: System Warning"
"Warning: Single Controller"
Product Description
Controller Module
23
Need help?
Do you have a question about the Surestore Disk Array 12h - And FC60 and is the answer not in the manual?
Questions and answers