5.
Shutdown the array using the front panel.
KEY
CANCEL CANCEL
MENU
-
-
ENTER
ENTER
After shutdown has completed, push the on/off button to the off position completing the
shutdown. This will turn off power to all modules.
6.
Disconnect all disk drive modules from the back plane. You do not need to remove them completely.
Just pull them out so that the cam handle is fully extended.
7.
Remove the controller that was noted as primary in one of the previous steps.
8.
Install the "third" controller into slot X. This may mean that you have to move the existing controller
into slot Y.
9.
Push the on/off button to the on position and allow the array to complete its initialization process. After
the initialization has completed, the front panel should say "Not Enough Disks". Check the system
state using the key strokes below. The System state should be "Not Enough Disks" with a "Firmware
Needed" warning.
KEY
CANCEL CANCEL
MENU
ENTER
+
HP SureStore E Disk Array 12H Controller
DISPLAY
"Ready"
"Language"
"View Settings"
"Shutdown"
"Confirm"
"Shutdown Complete"
DISPLAY
"Not Enough Disks"
"Language"
"View Settings"
"System State: Not Enough Disks"
"Warning: Firmware Needed"
Firmware Download Procedure