Troubleshooting
Event Code Descriptions
Event
Event Name
Number
(DEC/hex)
Internal SCSI
59/0x3b
Error
Internal Data
60/0x3c
Transfer Error
Host SCSI Bus
61/0x3d
Timeout
Reassign Failed
62/0x3e
Reassign Out Of
63/0x3f
Resources
Optimal Space
64/0x40
Error In RAID 5
148
Event
Predictive
Logged
Maintenance
Implication
N
More than
two per hot
plug event
Single
Y
Occurrence
Y
Ignore - Host
Reported Error
or
Compatibility
Y
Single
Occurrence
Y
Single
Occurrence
Y
Ignore
Suspected
Description
Components
Disk Drive
A disk drive responded
incorrectly. The result was an
Controller
internal SCSI bus reset, and a
Internal
hot-plug recovery sequence to
SCSI Bus
regenerate the bus state.
A data transfer failed due to a
Controller
parity error. This typically
Disk Drive
indicates a hardware problem.
Internal SCSI
Bus
Host SCSI
The target timed-out on a
SCSI transaction.
Bus Host
Controller
Disk Drive
The controller's attempts to
reassign a bad block failed due
to a disk drive error.
Disk Drive
The controller was unable to
complete a Reassign Blocks
command because the sparing
buffer is too small. There are
too many bad blocks in the
sparing buffer, indicating a
problem with the disk drive.
None
The controller detected that
space allocated for an
"optimal only" migrating write
(i.e. rebuild policy) was no
longer optimal after the write
had completed. This event is
logged for debugging
purposes only and requires no
action.