Troubleshooting
Event Code Descriptions
Event
Event Name
Number
(DEC/hex)
Internal SCSI
191/0xbf
Overrun Event
Internal SCSI
192/0xc0
Timeout Event
Controller ECC
193/0xc1
Miscorrection
Controller Data
194/0xc2
Bus
Microprocessor
Access Error
174
Event
Predictive
Logged
Maintenance
Implication
Y
Single
Occurrence not
accompanied
by other errors
Y
More than 2
occurrences
per hot plug
event
Y
Single
Occurrence
Y
Single
Occurrence
Suspected
Description
Components
Disk Drive
A disk drive sent/received
more data than expected.
Controller
Internal SCSI
Bus
Disk Drive
A disk drive didn't respond
within a specified time limit.
Controller
The disk drive may be failing,
Internal SCSI
or it may be busy performing
Bus
data retries.
SIMM
The system experienced a
Controller
correctable error which was
most likely miscorrected.
Controller
The controller experienced a
microprocessor access error
without the needed other
qualifiers. Microprocessor
access errors should only
occur in conjunction with
correctable or uncorrectable
memory errors, or with parity
errors. If no other condition is
present, this event is reported
to indicate the malfunction.