HP Surestore Disk Array 12h - And FC60 Service Manual page 171

Hp surestore e disk array 12h user's and service manual (c5445-90901, september 1999)
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

Event
Event Name
Number
(DEC/hex)
Data
178/0xb2
Unavailable
Insufficient
179/0xb3
Optimal Space
For Rebuild
Rebuild
180/0xb4
Restarted
Event
Predictive
Logged
Maintenance
Implication
Y
Ignore - See
accompanying
errors
Y
Ignore - See
accompanying
errors
Y
Ignore
Event Code Descriptions
Suspected
Description
Components
None
The data unavailable condition
was triggered. This is caused
by multiple failed, downed, or
missing disk drives. The
condition persists as a warning
until fewer than 2 drives are
down, failed, or missing.
If this condition occurred as a
result of removing disk drives,
reinstall them to correct the
problem.
This event also occurs if data
and redundancy have been lost
for any part of the disk set.
The disk array must be
reformatted in this case.
None
There is insufficient disk
space for rebuild to execute.
This event is most likely to
occur when using disk drives
of different capacities.
To create the necessary disk
capacity, add another disk
(equal in capacity to the
largest disk in the array) or
delete a LUN.
None
A rebuild has been
automatically restarted due to
a disk failure or a disk
removal.
Troubleshooting
171

Advertisement

Table of Contents
loading

This manual is also suitable for:

Surestore e disk array 12h

Table of Contents